Lincoln sp 125 plus problems - It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.

 
Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium .... The burger den denny

It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Lincoln SP-130; Lincoln spool gun ? SA200 - A Sheer Joy to Work on; lincoln tombstone tig ? Sp-130t; SA-200 wiring diagram; Pro-Mig 135 liner replacement problems; Buying my LN-25 Tomorrow :D :D; A/C D/C 225/125 mfg date. Lincoln-Pak 100 Mig conversion Quesion of regulator type; Lincoln is official welder of Jay Leno's garage; Lincoln ...Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.Welding Equipment. Lincoln SP-125 Plus Welder. Machine has not been used in 3 years. Worked when removed from service. buyer responsible to provide help to remove it. no loading dock. Request appointment at asset location to view previous to bidding. Visit site and verify condition before bidding.Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.Lincoln Electric: Forney: Lincoln Electric: Name: 120-Volt 140 Amp Easy Weld FC-i Flux Core Gasless Welder: 125 Amp Weld-Pak 125 Flux-Core Wire Feed Welder, 115V (No Gas) 140 Amp 120-Volt MIG Welder: Weld-Pak 180 Amp MIG Flux-Core Wire Feed Welder, 230V, Aluminum Welder with Spool Gun sold separately: Price $Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.Dec 30, 2019 · The Lincoln SP 125 is 120 volt and uses a 20 amp breaker. That is a problem with 120 volt welders. 1) see can change the welder to 240 volt some Lincoln welder can be changed. 2) I fix by buying a 240 volt welder. 3) cheat use a 30 amp breaker some will use the dryer breaker in the garage. 125 Amp 115-Volt Weld-Pak 125 HD Flux-Cored Wire Welder with .035 in. Flux-Core Welding Wire (1 lb. Spool) Whether you're working in the shop, on the Whether you're working in the shop, on the farm or at home, the Flux-Cored Welder is your go-to tool for basic wire welding projects and repairs. Simply plug in the welder where 120-Volt input ...No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.LINCOLN ELECTRIC 9SS15208 / Drive Pinion $95.10. LINCOLN ELECTRIC 9SM8776-83 / Key $11.69. LINCOLN ELECTRIC 9SS16645-2 / Bushing $1.34 ...To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Mar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantI have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .Lincoln SP-125 Plus Wire Feed Welder with Torch, Ground Clamp, Cart and More. LOT No: 142 Category: Welding Equipment. All Auction Items. Server time---buyer premium ...Anyone else going to the Lincoln Grand opening in LA? Lincoln SP-125 box welder; Lincwelder 225; lincoln 225 tig welder; Lincoln Wins Gold Medal in 2010 Olympics; Lincoln 180 DOA; Pro-cut 25, no start. lincoln Sp130t welder problem; Lincoln Weldanpower 225 G7; Lincoln Innershield 350 gun liner question; Lincoln Tig welder ruined; SA 200 ...Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantI was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.CHANGING DRIVE ROLL The SP-100 Wire Feed Drive Roll (1 ) has two grooves; one for 0.023” – 0.025” (0,6 mm) solid steel electrode and the other for 0.030” (0,8 mm) solid and 0.035” (O,9 mm) flux-cored steel electrode. Page 28 9. Screw the gas diffuser onto the end of the gun tube and securely tighten. 10.To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine.Re: sp 125 plus and aluminum. FYI I use a regular push gun on aluminum. I am taking a lunch break and going out to weld more of it. A teflon liner is a must. Use 5356 wire 4043 is to soft trust me I have a roll in mine right now. The cable must be kept as strait as posible and dont twist it.Sep 17, 2011 · #1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened. Lincoln Electric L-5254 Circuit Board L5254. $149.99 New. MILLER ELECTRIC 240978 USER INTERFACE MODULE CONTROL PANEL. $1,350.00 New.Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.Summary of Contents for Lincoln Electric IM536-D. Page 1 • World's Leader in Welding and Cutting Products • • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com RETURN TO MAIN MENU SP- 125 PLUS 10260, 10481,10685 ...If you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusOpinions on 305G Lincoln; Best engine Drive under 5000$ SP-125 Plus Amperage Question; Oil Fill on Perkins engine for Lincoln 300D; help..need parts for SA 200; Wire burning before touching metal; SP 250 stutter; SA-200 Engine Frozen; Invertec Questions; Newbie here with a dumb question; Power Mig 180C pricing? Brand new Lincoln Pro 180 for ...Screwing around with this machine and trying to teach myself to weld - a friend is selling to me over time for $300 which seemed like a good deal.... any way I started to use it and it was working just fine and the wire stopped feeding and some of the wire got tangled on the spool.Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.Hello. Info please. I have a used lincoln sp-125 hd. I bought this for a upcomming thin-wall exhaust project. Thought id get in some practice for a while before i attempt the actual thing. By the way the 125 is pretty dam powerful. I am using .025 lincoln solid wire with NO gas as I dont have a tank yet.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Drive Roll .035" For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $28.99. Save up to 5% when you buy more. Buy ...One sure sign is if the wire burns back in the contact tip. That could mean about 10 different things. Is this what is happening. John. SMAW,GMAW,FCAW,GTAW,SAW,PAC/PAW/OFC. and Shielding Gases.I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .Anyone else going to the Lincoln Grand opening in LA? Lincoln SP-125 box welder; Lincwelder 225; lincoln 225 tig welder; Lincoln Wins Gold Medal in 2010 Olympics; Lincoln 180 DOA; Pro-cut 25, no start. lincoln Sp130t welder problem; Lincoln Weldanpower 225 G7; Lincoln Innershield 350 gun liner question; Lincoln Tig welder ruined; SA 200 ...Scott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder. $28.99. $28.99. Lincoln 1pc MIG V-Knurl Drive Roll Kit KP3285-1. 4.1 out of 5 stars.02-04-2010 #1 Guard Solderer Join Date Feb 2010 Posts 4 Post Thanks / Like SP125 plus problems? Hello, I've had this for years w/gas bottle, and loved it so far! A few days ago trying to weld-up a snow blade for a 4-wheeler, It did fine for about 10 minutes, about 3-4 ins. of bead at a time, then quit putting anything out.Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding GunsIf you have any problems with the registration process or your account login, please contact support. Results 1 to 2 of 2 ... Lincoln SP 125 plusI was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.Product Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.Lincoln ElectricLincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.Dec 30, 2019 · The Lincoln SP 125 is 120 volt and uses a 20 amp breaker. That is a problem with 120 volt welders. 1) see can change the welder to 240 volt some Lincoln welder can be changed. 2) I fix by buying a 240 volt welder. 3) cheat use a 30 amp breaker some will use the dryer breaker in the garage. Dec 30, 2019 · The Lincoln SP 125 is 120 volt and uses a 20 amp breaker. That is a problem with 120 volt welders. 1) see can change the welder to 240 volt some Lincoln welder can be changed. 2) I fix by buying a 240 volt welder. 3) cheat use a 30 amp breaker some will use the dryer breaker in the garage. Wire welder feed, but no arc (spark) 10-20-2012, 08:43 PM. I have a millermatic 150 that I bought used a few years ago. It has been an amazing welder. I was welding the other day and in the middle of a bead, it stopped welding. I have had this happen before and waited to let it cool and continued on.Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.I bought a new lincoln SP-125 plus, probably 8-10 years ago, for packing upstairs on the back deck to do final installations on railings. The little guy does okay in the shop, but I quickly noticed that electricians just can't see the merit in running a #12 wire with a 20 amp breaker upstairs to the back deck of any house.Lincoln Electric® Input Cord is designed to use with SP-125 plus welding system. We use cookies to improve your browsing experience and help us improve our websites. By continuing to use our website, you agree to our use of such cookies.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13Looking for parts for Lincoln mig welder sp130t, – – Looking for parts for Lincoln mig welder sp130t, need part m15787-2, g1839,and drive roll, Any idea where to – MIG Welders question Lincoln Welder – Farm Supply Ranch – lincoln electric k639 1 suction head manual 12 inch lincoln sp 125 plus arc welder in excellent condition 9.99 ...Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Lincoln Electric. $118.81 ) +Free Shipping. SKU: S24355-4. Quantity: Decrease Quantity: Increase Quantity: Only left in stock! Adding to cart… category.add_cart ...A short stick of welding filler metal consisting of a core of bare electrode covered by chemical or metallic materials that provide shielding of the welding arc against the surrounding air. It also completes the electrical circuit, thereby creating the arc. (Also known as SMAW, or Stick Metal Arc Welding.)Tips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderScott you did notice though that I cast a vote for the SP 135 over the MM 135. Untill Miller decides to change the variable voltage with wire speed tracking idea the Lincioln will be the leader between the two. MigMaster 250 - Smooth arc with a good touch of softness to it. Good weld puddle wetout.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.Contact us by phone at 888-935-3877. Service & Distributor Locator. Print & Pdf Publications: REQUEST LITERATURE. COUNTERTOP PARTS GUIDE. (20 mb PDF) service navigator: video tips.Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Lincoln Electric

Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.. How much does a cashier at lowepercent27s make an hour

lincoln sp 125 plus problems

SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantHome › SP-125 PLUS HTP Flex Neck Gun & Parts SP-125 PLUS HTP Flex Neck Gun & Parts HTP America® 15 Series flex neck MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Tips Nozzle Diffuser Liner fits Lincoln SP-135 Plus SP-135T MIG Welder ILS 41.80 to ILS 121.66 Tips Nozzle Diffuser Liner fits Lincoln SP-85 SP-100 SP-100-I SP-100T MIG WelderSOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. Lincoln ElectricMar 23, 2017 · Do this, you have to the wire back on to the reel. Once the gun is off, take a small piece of mig wire, bent into a u shape and poke it into the two gun switch cables. This will bridge the switch circuit and make the welder feed. If it works, the problem is the gun, (tip, liner) and if it doesnt, the issue is somewhere else in your machine. Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. Sep 17, 2011 · #1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened. My second , a Lincoln SP125 Plus, lots of years ago. Use it weekly. I mainly do body panel rust repair on vintage sports cars, ie thicker carbon steel. My son is 50 miles away with projects too. I need to stage a welder there. I liked my welder so much I found one like it for him, but it needs some parts. I know Lincoln did't make it.Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.I had two mm130 one was a 130 xp. I would say a fair comparison would be to a Lincoln sp 125 plus. The cost was about even ($500.00 new) The MM 130 was really not much of a welder but the xp version could more then hold it's own with the 125 Lincoln. I prefer the MM 130 xp over the new MM 135, My XP came with the Hobart OXO gun, that was really ...I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250.Loosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut..